Aruba 2930F 24G 4SFP+ Switch (JL253A)

Aruba 2930F 24G 4SFP+ Switch (JL253A)

    Fiyat Teklifi Alın

    SPECIFICATIONS
    Aruba 2930F 24G 4SFP+ Switch (JL253A)
    I/O ports and slots
    24 RJ-45 autosensing 10/100/1000
    ports (IEEE 802.3 Type 10BASE-T,
    IEEE 802.3u Type 100BASE-TX, IEEE
    802.3ab Type 1000BASE-T); Duplex:
    10BASE-T/100BASE-TX: half or full;
    1000BASE-T:full only
    4 SFP+ 1/10GbE ports; PHY-less
    Additional ports and slots
    1 dual-personality (RJ-45 or USB micro-B) serial console port
    Physical characteristics
    Dimensions 17.42 (w) x 11.98 (d) x 1.73 (h) in
    (44.25 x 30.42 x 4.39 cm) (1U height)
    Weight 5.31 lb (2.41 kg)
    Memory and processor
    Dual Core ARM Cortex A9 @ 1016
    MHz, 1 GB DDR3 SDRAM; Packet
    buffer size: 12.38 MB
    4.5MB Ingress/7.875 Egress,
    4 GB eMMC
    Performance
    IPv6 Ready Certified
    1,000 Mb Latency < 3.8 μs (64-byte packets)
    10 Gbps Latency < 2.9 μs (64-byte packets)
    Throughput up to 95.2 Mpps
    Switching capacity 128 Gbps
    Routing table size 2,000 IPv4, 1,000 IPv6 in hardware,
    200 OSPF, 256 Static, 10,000 RIP
    MAC address table size 32,768 entries
    Environment
    Operating temperature 32°F to 113°F (0°C to 45°C); up to
    5,000 Feet, 0°C to 40°C (32°F to
    104°F) up to 10,000 Feet
    Operating relative humidity 15% to 95% @ 104°F (40°C)
    noncondensing
    Non-operating/Storage

    temperature

    -40°F to 158°F (-40°C to 70°C); up
    to 15,000 Feet
    Non-operating/Storage

    relative humidity

    15% to 95% @ 149°F (65°C),
    noncondensing
    Airflow direction Side-to-side
    Electrical characteristics
    Frequency 50/60 Hz
    Power efficiency

    certifications

    Maximum heat dissipation 100.0 BTU/hr (105.5 kj/hr)
    Voltage 100 - 127 / 200 - 240 VAC, rated
    Current 0.6/0.4 A
    Maximum power rating 29.3 W
    Idle power 19.5 W
    PoE power
    Notes Idle power is the actual power consumption of the device with no ports connected. Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers
    provided for planning the in frastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
    Safety
    UL 60950-1: 2nd Edition;
    UL 62368-1: 2nd Edition;
    EN 60950-1:2006 +A11:2009
    +A1:2010 +A12:2011+A2:2013;
    EN 62368-1: 2nd Edition;
    IEC 60950-1:2005 +A1:2009
    +A2:2013; CSA 22.2 No. 60950-1-07
    2nd; IEC-62368-1: 2nd Edition;
    EN 60825-1:2014 / IEC 60825-1:
    2014 Class 1
    Emissions
    EN 55032:2012/CISPR 32 Class A;
    FCC CFR 47 Part 15 Class A; VCCI
    Class A; ICES-003 Class A;
    CNS 13438
    Immunity
    Generic EN 55024:2010/CISPR 24
    ESD IEC 61000-4-2
    Radiated IEC 61000-4-3
    EFT/Burst IEC 61000-4-4
    Surge IEC 61000-4-5
    Conducted IEC 61000-4-6
    Power frequency
    magnetic field
    IEC 61000-4-8
    Voltage dips and
    Interruptions
    IEC 61000-4-11
    Harmonics IEC/EN 61000-3-2
    Flicker IEC/EN 61000-3-3
    Management
    Aruba Central; Aruba AirWave
    Network Management; IMC –
    Intelligent Management Center;
    Command-line interface; Web
    browser; Configuration menu;
    SNMP manager; Telnet; RMON1;
    FTP